Ionic Cleanse Machine
Modle:H708Ionic cleanse machine detox your body through foot.
Aok Ion Cleanse/Ion Cleanse Machine H708
description:
Net Weight: 1.5KG
Gross Weight: 3.5KG
Outside Packing: 41CM * 29CM * 15.5CM (L*W*H)
Product Packing: 65CM * 43CM * 33.5CM (L*W*H)
Voltage: 110V/220V
Power: 30W
Current: 0.5~ 2.5A
The packing type:Aluminum box
Inside box:Aluminum box
The outside box:Common cardboard box
H 708 A :Have no the electronics wrist to take
H708 B:There is the electronics wrist to take
Main characteristics:Big screen English manifestation, operation
simple,
1. Before using the machine, be sure to read through this
instruction manual.
2. This product is designed for only use on healthy person.
The four main parts:
Main machine; 1PCS;
array ;1PCS;
Power line
Wrist band1 pc ( just use for K608B model )
The preparation before use:
Open the box, take out of the main machine and electrode plate,
put them in good place for use.
Connect the power line.
Connect the electrode plate with the main machine.
Put the electrode plate in water.
It don’t need muscle test if not special treatment. Just open the
main machine power.
Press the button of OK” to enter the mode choice; press +” or - to
choose the suitable mode. Now there are five modes for choice.
Normal people usually choose the third mode.
Bath your feet in water after finishing choosing the mode, press
ok” to start setting the time through +” or -; usually set 30
minutes original. If no need to change, press ok” directly.
Repress OK” to confirm it and press START” to start working;
Mode choices:
Though there are usually five modes for choices, because we just
use it for normal daily health care, as the common user, suggestion
is to choose the third mode with (70+/30- OPTION). It doesn’t need
the muscle test.
a) All positive electricity: for clinic test usage;
b) All negative electricity: just only for clinic test usage;
Not only all positive but also negative electricity, if use them
extremely, it will induce the PH of acid and alkali volume uneven.
c) 70+/30-: It is very popular suitable for most of people;
d) 15+/10-/5+:
e) 10-/15+/5-:
f) After over several thousands muscle test, if the reaction from
muscle is positive at first, please choose the mode of d”; if
contrarily, please choose e”.
Remarks
Please note as following:
It should maintain normal blood pressure when any medicine
treatments. It must use before the medicine treatment to bath feet
by the ion cleanse to keep a natural blood pressure.
If low blood pressure, please have something first. The machine may
decrease blood sugar.
The pregnant or lactation women please don’t use it, because it
maybe dredge out the toxins of the tissue and grease and block
producing milk nutrition that is necessary to the infant body.
Although not any prove it with bad impaction, but for safety, we
suggest no use.
It can be used to the person who is receiving kidney dialysis,
hormone insulin medicament and the heart symptom like congestive
and half-baked. The machine can help the body to get rid of the
toxin that cannot be cleaned by the kidney and heart. It will not
impact the medicine treatment and decrease the index of insulin.
Someone who accept the replanting surgical of the metal arthrosis,
if feel uncomfortable under the magnetic, please stop the foot bath
at once.
After use, please make up nutrition absorption such as vitamin,
mineral, fatty acid and etc to promote the body metabolism and
eject the toxin by itself.
Common troubles
If over 2.8 Amp, it shows the panel wrong with alarm coming. It
means high output and then the power off automatically.
If both the current and the voltage are very low, the main machine
without good radiation and the panel heavy loaded.
If the power is on, but no information after 30 seconds, for
example of the voltage, ampere which will be usually displayed
every three seconds. Please refer to the reasons as following:
The array not in water;
The electric conduct of the water is not enough, like the distilled
water, suggestion is to add a little salts and mix round to enhance
it. When the plate in water, the normal current is between 1.8 and
2.5 ampere, the voltage is between 12 and 18V.
The wire of the array is not connected with the main machine.
There are damages or troubles with the wire of the plate, plug or
connecting status.
The main machine troubles.
Course suggestion:
All people ove